MW-H -
Hot Water Meters |
|
|

FEATURES
• Inbuilt
water strainer
• Complete with couplings
• Corrosion proof copper alloy body
• Dry dial dial |
 |

 |
|
 |
|
| |
 |
 |
 |
MW-HM601 -
Heat Meter Integrator |
|
|

DESCRIPTION
The MW-HM601 Series
is designed to measure and record heat energy in installations
where water is the primary heat transfer medium. The
most common application for heat meters is to provide
accurate energy consumption data for sub-metering or
billing purposes.

FEATURES
• Battery
backup
• Data logging for up to 15 years
• Measures heating or cooling and heat/cooling
• LonWorks® versions available |
 |

 |
|
| |
|
| |
 |
 |
 |
MW-65-1 -
Ultrasonic Cooling Meters with Integrator |
|
|

DESCRIPTION
The MW-65-1 Series
is used for the measurement of cooling systems, with
flow temperatures from 2 to 50°C.
The flow is measured using bi-directional ultrasonic
technique based on the transit time method, with long-term
proven stability and accuracy. The meter is not suitable
for use with any other media than water, and should not
be used with non-freezing additives like glycol.

FEATURES
• Ultrasonic
flow meter
• Large dynamic range
• Longevity
• LonWorks® versions available |
 |

 |
|
| |
|
| |
 |
 |
 |
MW-65-5 -
Ultrasonic Heating Flow Meters |
|
|

DESCRIPTION
The MW-65-5 Flow
Meter is used to measure volumetric flow rate where the
primary heat transfer medium is water. It is used in
conjunction with the MW-HM601 energy meters, and is based
on an ultrasonic technique.
The flow is measured using bi-directional ultrasonic
technique based on the transit time method, with long-term
proven stability and accuracy.

FEATURES
• Ultrasonic
flow meter
• Large dynamic range
• Longevity
• No moving parts |
 |

 |
|
| |
|
| |
 |
 |
 |
MW-HM401 -
Ultrasonic Heat Meter |
|
|

DESCRIPTION
This Ultrasonic
Thermal Heat Meter is designed for measuring energy in
all types of heating installations.
The meter can be installed as a single unit, or the calculator
and flow meter can be placed at a distance of up to 1.4m
from each other. The flow meter is available in sizes
from qp 0.6 to 15m3/h, either with threaded or flanged
connections.

FEATURES
• Long
life ultrasonic flow meter
• Pulsed or M-bus output options
• Simple to install and read |
 |

 |
|
| |
|
| |
 |
 |
 |
MW-M-BUS -
Heat Meter Integrator (M-Bus Network) |
|
|

DESCRIPTION
Using the MW-HM601
Heat Meter Integrator with an M-bus output card, up to
250 integrators may be connected together on a network.
The system utilises an M-bus sub master unit with a cascade
module to collect the information from up to 38 stations
on each sub-LAN. Flexibility of M-bus architecture allows
low cost installation to suit the building layout using
twister pair cabling.
A central M-Bus master collects
the information from the cascade modules and feeds the
data to a PC. Using MW-PCBASE3 and MW-PCNET3 software,
the PC is able to exchange data with a host of billing
packages and Excel software using DDE links within MS
Windows.

FEATURES
• Twisted
pair cabling for low cost installation to 12,000m
• Up to 250 Integrators on a single network,
38 per sub-network
• M-bus software for reliability and stability
• Windows based PcM-bus Software stores all
data and features consumer register of connected
utilities
• System data can be exported to accounting,
billing and worksheet programs |
 |

 |
|
| |
|
| |
 |
 |
 |
MW-CHM -
Compact Heat Meters |
|
|

DESCRIPTION
Sontay’s
range of Water Meter and Heat Meter Integrator packages,
comprises of a water meter, heat meter integrator, matched
pair of high accuracy temperature sensors and pockets.
The temperature sensor length is 3m, supply module is
battery and output is pulsed, as standard. Optional 10m
sensor pair, 230Vac supply and M-bus options are available.
The microprocessor-controlled calculator has a large,
easy-to-read display that constantly shows the energy
used. The integrated non-volatile E2PROM automatically
stores the meter data six times a day. It is possible
to view the last 12 monthly values from the display.

FEATURES
• Simple
operation
• Pulsed output (standard) or M-bus options
• Wall bracket included |
 |

 |
|
| |
|
| |
 |
 |
 |
MW-DM -
Water and Heat Meter Integrator Packages |
|
|

DESCRIPTION
The MW-HM601 Series
is designed to measure and record heat energy in installations
where water is the primary heat transfer medium. The
most common application for heat meters is to provide
accurate energy consumption data for sub-metering or
billing purposes.

FEATURES
• Battery
backup
• Data logging for up to 15 years
• Measures heating or cooling and heat/cooling
• LonWorks® versions available |
 |

 |
|
| |
|
| |
 |
 |
 |
MW-DHM -
Heat Meter Integrators |
|
|

DESCRIPTION
The MW-DHM range
of Meter Integrators is available with either a pulsed
output or M-bus output. Up to a maximum of 250 integrators
can be connected on a M-bus network.
Integrators come with a matched pair of high accuracy
temperature sensors and pockets. As standard, the temperature
sensors lead length is 3m and supply module is battery.
Optional 10m sensor pair and 230Vac supply are available
upon request.
The microprocessor-controlled calculator has a large,
easy-to-read display that constantly shows the energy
used. The integrated non-volatile EÇPROM automatically
stores the meter data six times a day. It is possible
to view the last 12 monthly values from the display.

FEATURES
• Simple
operation
• Pulsed output or M-bus output options
• Wall bracket included |
 |

 |
|
| |
|
| |
|